EuroPCR 2015: Safety and Biomarker Effects of a Novel Multi-electrode Over-the -Wire Renal Denervation RF Catheter in a Porcine Model

Tzafriri AR; Bailey L; Keating JH; Markham PM; Regan K; Prutchi D; Edelman ER. ‘Safety and Biomarker Effects of a Novel Multi-electrode Over-the -Wire Renal Denervation RF Catheter in a Porcine Model.’ Summary: Clinical studies and renal artery innervation patterns suggest that the efficacy of RF renal denervation (RDN) increases with increasing number of electrode treatments. […]

CRT 2015: Particulates from Hydrophilic Coated Guiding Sheaths Embolize to the Brain

Stanley JRL, Regan K, LaRochelle A, Zani B, Markham PM, Bailey L, Spognardi A, Wong G, Tzafriri AR, Kopia G, Edelman ER. ‘Particulates from Hydrophilic Coated Guiding Sheaths Embolize to the Brain.’ Summary: Peripheral vascular interventions frequently employ guiding sheaths with hydrophilic coatings raising the concern for the embolization of this material clinically as increasingly documented. […]

CRT 2015: Preclinical Safety and Efficacy of a Novel Multielectrode Bipolar/Unipolar Over-the-Wire Renal Denervation RF Catheter

Tzafriri AR, Bailey L, Keating JH, Markham PM, Prutchi D, Edelman ER. ‘Preclinical Safety and Efficacy of a Novel Multielectrode Bipolar/Unipolar Over-the-Wire Renal Denervation RF Catheter.’ Summary: Clinical and preclinical studies suggest that the efficacy of RF renal denervation (RDN) increases with increasing number of treatments. We evaluated efficacy and safety of the 9-electrode, 5-Fr, over-the-wire, […]

CRT 2015: Minimal Plaque Surface Area and Minimal Luminal Area Needed for Effective Atherectomy using the JetStream Navitus in Treating In-Stent Restenosis of Femoral Artery in a Porcine Model

Shammas NW, Aasen N, Bailey L, Budrewicz J, Farago T, Jarvis G. ‘Minimal Plaque Surface Area and Minimal Luminal Area Needed for Effective Atherectomy using the JetStream Navitus in Treating In-Stent Restenosis of Femoral Artery in a Porcine Model.’ Summary: The JetStream Navitus (JS) atherectomy device is a rotational cutter with aspiration capability designed to treat […]

CRT 2015: Intravascular Ultrasound Assessment of the Optimal Number of Runs Using the JetStream Navitus Device to Achieve Maximum Tissue Debulking in Femoral Artery in-Stent Restenosis Porcine Model

Shammas NW, Aasen N, Bailey L, Budrewicz J, Farago T, Jarvis G. ‘Intravascular Ultrasound Assessment of the Optimal Number of Runs Using the JetStream Navitus Device to Achieve Maximum Tissue Debulking in Femoral Artery in-Stent Restenosis Porcine Model.’ Summary: The JetStream Navitus (JS) atherectomy device (Boston Scientific) is a rotational cutter with aspiration capability to treat […]

CRT 2015: Optimal Number of Runs Using the JetStream Navitus Device to Achieve Maximum Tissue Debulking of in-Stent Restenosis in a Porcine Stent/Balloon Injury Overstretch Model

Shammas NW, Aasen N, Bailey L, Farago T, Jarvis G. ‘Optimal Number of Runs Using the JetStream Navitus Device to Achieve Maximum Tissue Debulking of in-Stent Restenosis in a Porcine Stent/Balloon Injury Overstretch Model.’ Summary: The JetStream Navitus (JS) (Boston Scientific) is an atherectomy device that uses rotational cutting and aspiration to treat infringuinal arterial obstructive […]